Ergebnisse NRP PC402
| Stability: 12V |
|
12V CPU Loadless
|
|
|
12V GPU Loadless
|
|
|
12V CPU Low
|
|
|
12V GPU Low
|
|
|
12V CPU Mean load (350W)
|
|
|
12V GPU Mean load (350W)
|
|
|
12V CPU 100% rail (20A)
|
|
|
12V GPU 100% rail (20A)
|
|
|
12V CPU Full load (400W)
|
|
|
12V GPU Full load (400W)
|
|
|
| |
|
volts |
| Stability: -12V |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
Full load (400W)
|
|
|
| |
|
volts |
| Stability: 5V |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
100% rail (15A)
|
|
|
Full load (400W)
|
|
|
| |
|
volts |
| Stability: 5V Stand-by |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
Full load (400W)
|
|
|
| |
|
volts |
| Stability: 3.3V |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
100% rail (24A)
|
|
|
Full load (400W)
|
|
|
| |
|
volts |
Die maximale Abweichung der Schienen betrug -6.5% nach unten (low -12V) und 2% nach oben (loadless 3,3V) und liegt damit deutlich innerhalb der Toleranz von 5% (loadless 3,3V) bzw. 10% (low -12V). Dabei haben wir bei beiden Modellen alle 12V-Schienen für CPU, Grafikkarte und Laufwerke (soweit vorhanden), sowie die 5V Schiene und die 3,3V Schiene gesondert belastet und gemessen. Kleine Spannungsabweichungen werden aber immer auch durch die Kabel mit verursacht.
Ergebnisse NRP PC502
| Stability: 12V |
|
12V CPU Loadless
|
|
|
12V GPU Loadless
|
|
|
12V CPU Low
|
|
|
12V GPU Low
|
|
|
12V CPU Mean load (350W)
|
|
|
12V GPU Mean load (350W)
|
|
|
12V CPU 100% rail (20A)
|
|
|
12V GPU 100% rail (20A)
|
|
|
12V CPU Full load (500W)
|
|
|
12V GPU Full load (500W)
|
|
|
| |
|
volts |
| Stability: -12V |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
Full load (500W)
|
|
|
| |
|
volts |
| Stability: 5V |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
100% rail (15A)
|
|
|
Full load (500W)
|
|
|
| |
|
volts |
| Stability: 5V Stand-by |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
Full load (500W)
|
|
|
| |
|
volts |
| Stability: 3.3V |
|
Loadless
|
|
|
Low
|
|
|
Mean load (350W)
|
|
|
100% rail (24A)
|
|
|
Full load (500W)
|
|
|
| |
|
volts |
Die maximale Abweichung der Schienen betrug -6.3% nach unten (low -12V) und 1.8% nach oben (loadless 12V2) und liegt damit deutlich innerhalb der Toleranz von 5% (loadless 3,3V) bzw. 10% (low -12V).