Thermalright HR-02 CPU Kühler im Test

Seite 4: Testlauf/Temperaturen

Messung:

Temperaturen CPU Thermalright HR-02
Temperaturen CPU Standard
Thermalright HR-02 TY140mm 1200 U/min und 120mm Noctua 1000 U/min
40
57
Thermalright HR-02 TY 1200 U/min
40
59
Thermalright HR-02 TY 600 U/min
42
64
Thermalright HR-02 Semi-Passiv
51
91
 
0
100
50
°C


Temperaturen CPU
Temperaturen CPU Standard
Noctua NH-D14/High 3 Lüfter
12.0
27.7
Cogage Arrow/High 3 Lüfter
10.7
27.8
Thermalright HR-02 TY140mm 1200 U/min und 120mm Noctua 1000 U/min
10.8
27.8
Corsair H50/High 2 Lüfter
10.8
27.8
Prolimatech Megahalems Noctua 1350 U/min
12.2
29.0
Thermalright VenomousX 2x Noctua 1350 U/min
12.5
29.2
Scythe Ninja 3 1800 U/min
12.0
29.5
Thermalright HR-02 TY 140mm 1200 U/min
11.3
30.3
Alpenföhn Matterhorn 1500 U/min
12.1
31.0
Titan Fenrir Evo 2200 U/min
12.7
31.1
Tuniq Tower 120 Extreme/High
14.4
31.5
CoolIT Eco 1800 U/min
14.3
32.2
Cooler Master V10/High
11.6
34.6
Thermalright HR-02 TY 140mm 600 U/min
13.4
35.4
Cooler Master V8/High
13.1
36.1
Alpenföhn Nordwand
16.6
36.6
Spire TherMax II 2400 U/min
11.8
37.8
Cooler Master Hyper 212 Plus 1900 U/min
15.3
38.3
Xigmatek Balder
15.8
39.8
Akasa Nero-S 1500 U/min
13.3
40.3
Scythe Rasetsu 1850 U/min
13.6
40.6
Scythe Yasya 1900 U/min
13.9
40.9
Intel Boxed (Neu)800/2600 U/min
22.1
41.1
Cooltek CoolForce 2000 U/min
19.0
43.0
Intel Boxed (Neu) 800/1800 U/min
23.1
43.1
Scythe Samurai ZZ 2600 U/min
16.4
44.4
Titan Skalli 1500 U/min
17.5
44.5
Thermaltake Contac 29 2000 U/min
17.6
44.6
Thermalright HR-02 Semi-Passiv
22.4
62.5
 
0
100
50
Delta-T (K)


Temperaturen CPU/3,8 GHz/1,4V
Temperaturen CPU 3,8 GHz
Thermalright HR-02 TY140mm 1200 U/min und 120mm Noctua 1000 U/min
14.9
50.9
Cogage Arrow/(Noctua 120+140mm 1000 U/min)
16.9
51.9
Thermalright HR-02 TY 1200 U/min
15.0
52.0
Noctua NH-D14 (Noctua 120+140mm 1000 U/min)
17.9
52.9
Thermalright HR-02/(Noctua 120+140mm 1000 U/min)
15.1
53.1
Prolimatech Megahalems Noctua 1000 U/min
17.2
54.0
Cooler Master V10/High
17.5
54.5
Thermalright VenomousX/(2x Noctua 1000 U/min)
18.5
54.5
Corsair H50 (Noctua 1000 U/min)
17.8
54.8
Alpenföhn Matterhorn (Noctua 1000 U/min)
19.1
55.1
Cogage True Spirit (Noctua 1000 U/min)
18.2
55.1
CoolIT Eco (Noctua 1000 U/min)
18.2
55.2
Alpenföhn Nordwand (Noctua 1000 U/min)
20.5
56.5
Thermalright HR-02 TY 600 U/min
18.9
58.9
Cooler Master V8/High
20.9
60.8
Titan Fenrir Evo 2200 U/min
18.9
60.9
Scythe Ninja 3 (Noctua 1000 U/min)
22.0
61.0
Tuniq Tower 120 Extreme
17.6
61.5
Xigmatek Balder (Noctua 1000 U/min)
20.9
67.9
Boxed Kühler (Neu) Performance
31.0
67.0
Thermaltake Contac 29 2000 U/min
24.6
67.5
Spire TherMax Eclipse (2x Noctua 1000 U/min)
20.8
68.4
Titan Skalli 1500 U/min
24.6
68.6
Scythe Rasetsu 1850 U/min
22.7
68.7
Scythe Yasya (Noctua 1000 U/min)
25.0
69.0
Zerotherm Core92 PWM
25.1
70.1
Akasa Nero-S (Noctua 1000 U/min)
22.2
70.2
Cooltek CoolForce 2 2000 U/min
26.8
70.8
Cooler Master Hyper 212 Plus (Noctua 1000 U/min)
23.2
71.4
Scythe Samurai ZZ 2600 U/min
25.7
74.5
Boxed Kühler (Neu) Quiet
32.0
75.0
 
0
100
50
Delta-T (K)


Temperaturen CPU/3,8 GHz direkter Lüftervergleich
Lüftervergleich
Temperaturen CPU 3,8 GHz
Thermalright HR-02 TY140mm 1200 U/min und 120mm Noctua 1000 U/min
14.9
50.9
Thermalright HR-02 TY 1200 U/min
15.0
52.0
Thermalright HR-02/(Noctua 120+140mm 1000 U/min)
17.9
52.9
Thermalright HR-02 TY 600 U/min
18.9
58.9
 
0
100
50
Delta-T (K)



Der Thermalright HR-02 zeigt in fast allen Bereichen eine überragende Kühlleistung und ordnet sich bei uns ganz oben in der Kühler-Liste mit ein. Zwar ist ein Semi-Passiv Betrieb durchaus möglich, jedoch werden etwas schneller drehende Gehäuselüfter zwingend erforderlich. Wir empfehlen hier klar langsam drehende Lüfter auf dem HR-02 selbst einzusetzen. Der TY-140 löst seine Aufgabe hervorragend und in den genannten Drehzahlbereichen zwischen 600 U/min und 1.200 U/min bleibt er im Gehäuse stets unhörbar im Hintergrund. Messungen konnten wir mit unserem Messgerät aufgrund der niedrigen Lautstärke nicht mehr zuverlässig machen. Für einen Thermalright Lüfter war dies in der Vergangenheit nicht immer so.
Nächste Seite: Fazit
Veröffentlicht:

Kategorie: Kühler
Kommentare: 0